Specifications:
- Model: W1209
- Temperature Control Mode: ON / OFF
- Temperature Range: -50°C – 110 °C
- Resolution: When Temperature between -9.9 °C to 99.9 °C, Resolution is 0.1°C, Other Temperature Values, the resolution is 1°C
- Control Accuracy: 0.1°C
- Hysteresis Accuracy: 0.1°C
- Refresh Rate: 0.5S
- High-Temperature Protection: 0-110 °C
- Supply Voltage: DC 12V
- Static Current: ≤35mA, Attract Current ≤65mA
- Input Voltage: DC 12V
- Output Power: 10A Relay
- Measurement Input: NTC (10K 0.5%) Waterproof Sensor
Setting Table |
|||
Press The “SET” Key to Enter the Main Menu |
|||
Code | Code Description | Setting Range | The Factory Setting |
P0 | Cooling / Heating | C / H | C |
P1 | Hysteresis Setting | 0.1 – 15 | 2 |
P2 | Maximum Set Cap | 110 | 110 |
P3 | Minimum Set Limit | -50 | -50 |
P4 | Temperature Correction | -7.0 ~ 7.0 °C | 0 |
P5 | Delayed Start Time | 0 – 10 minute | 0 |
P6 | High-Temperature Alarm | 0 – 110 °C | OFF |
Off-state to press “+ -” to power, can restore to the factory settings |